Back wall height above the side walls
Back wall header above the side wall height; display advertising area.
Trays and displays / JETDIELINE
Open display for the shop counter: low front wall with finger recess, tall back wall with advertising area, sloping side walls; corners are glued inside with corner glue flaps as on the tray.


Drag to rotate
03 / BOX
Simplified display model with indicative material thickness, not to scale.
The 3D view is not available in this browser. The image shows the folded shape.
carton.display.counterA base joins the low front wall, tall back wall with header and trapezoidal side walls. Corner glue flaps join the walls. The optional front cut-out makes the goods easier to access.
Erect front and back walls, fold the corner glue flaps inwards and apply adhesive to their outside. Erect side walls and press against the flaps. Insert goods; the back wall shows the advertising area.
Test fit, folding and closure on a sample made from the intended material. Confirm material thickness, grain direction and production steps with your printer.
Inside dimension
These dimensions describe the preview, not a fixed packaging size. The app recalculates the dieline for your own dimensions.
Back wall header above the side wall height; display advertising area.
Inside height of the front wall; the side walls rise from it to the height at the back wall.
Round finger recess centred in the front wall's top edge for easy removal of goods.
Radius and depth of the finger recess; a bridge remains above the bottom and towards the corners.
Width of the glue flaps at the ends of the front and back walls, which are glued to the inside of the end walls. The material requires a minimum width; flaps from both sides must not meet on the end wall.
The third input is the construction's base height. The low front wall has its own parameter, as does the back wall height above the side walls. The header is therefore not simply the third input. In the starting run, base height is 100 mm, front wall height 40 mm and additional back wall height 120 mm.
Front and back walls have corner glue flaps. The side walls are pressed against the adhesive-coated flaps. There is no locking closure like that of the tray with interlocking corners. Glue flap width and angle must suit wall and gap. Check erection and curing with the intended adhesive before loading the display with goods.
The frontCutout switch starts enabled and can be disabled. The radius is only needed for an enabled cut-out. When enabled, the cut-out's width and depth must fit the front wall. A geometrically valid radius does not describe removal force; test access with the actual product and its packing arrangement.
Find the right packaging shape and fit it to your product
Design the artwork directly on the real dieline
Spot problems before you pass on files
Files your printer can trace
With JetDieline, choose a suitable template, adjust its size, and place text, logos, and images directly on your packaging.
Try your dimensions